The master's thesis developed an automated system for assessing the quality and effectiveness of cardiopulmonary resuscitation. The explanatory note contains the following components: a list of symbols and abbreviations, an introduction, four sections of the main material, the development of a startup project, conclusions and a list of references to the sources used. In total, the master's thesis contains 102 pages, 18 figures, 30 tables and 30 references.
Purpose and objectives. Development of an automated system for assessing the quality and effectiveness of cardiopulmonary resuscitation designed to help lay rescuers who are forced to perform resuscitation measures directly at the scene of an accident, before the arrival of medical workers.
Thesis objectives:
1. Analysis of the current state of the problem of assessing the quality and effectiveness of cardiopulmonary resuscitation
2. Analysis of existing systems for assessing the quality and effectiveness of cardiopulmonary resuscitation, determining the principle of their operation, advantages and disadvantages
3. Development of a structural diagram of an automated system for assessing the quality and effectiveness of cardiopulmonary resuscitation
4. Development of an algorithm for the operation of the system for assessing the quality and effectiveness of cardiopulmonary resuscitation
5. Consideration of the possibilities of technical implementation of the system, selection of materials and development methods
6. Development of a circuit diagram of an electrical automated system for assessing the quality and effectiveness of cardiopulmonary resuscitation
7. Development of a mock-up of an automated system for assessing the quality and effectiveness of cardiopulmonary resuscitation
Object of the study. The process of assessing the effectiveness of cardiopulmonary resuscitation. research.
Subject of the study. Automated system for assessing the effectiveness of cardiopulmonary resuscitation.
Practical significance of the obtained results:
1. A structural diagram of an automated system for assessing the effectiveness of cardiopulmonary resuscitation has been developed, a block diagram of the algorithm of the automated system for assessing the quality and effectiveness of CPR has been developed
2. An electrical schematic diagram of an automated system for assessing the effectiveness of cardiopulmonary resuscitation has been developed
3. A block diagram of the algorithm of the automated system for assessing the effectiveness of cardiopulmonary resuscitation has been developed
4. A model of an automated system for assessing the quality and effectiveness of CPR has been developed
Research advisor: I. Cherepanska